This service factor is a certain load without impact and based on 8 hours a day. You can select the decelerator by calculating the equivalent load by multiplying load factor to the load.
Operation Time / Load | Impact | |
---|---|---|
Normal | Severe | |
~10 hours/day | 1.0 | 1.4 |
24 hours/day | 1.2 | 1.6 |
※ Required Horsepower = Calculated horsepower × Load factor
Motorization type | Cf |
---|---|
Chain | 1.0 |
Gear | 1.25 |
V-Belt | 1.5 |
(Table 2) Factor of motorization
Place of load | Lf |
---|---|
1.0d | 1.0 |
1.5d | 0.8 |
2.0d | 0.7 |
(Table 3) Factor of place of load